Portland Cement type 2

Portland cement Type 2 Application
- In cases that a cautious action is needed towards average attack of sulfates.
- Because of hydration reaction in low speed in this type of cement less heat is produced. So this type of cement can be used in almost massive structures like large pillars of big bridges and heavy retaining walls.
- Using this type of cement increases the temperature, this specialty is important in formwork in hot weather.
- In addition to aforesaid cased in all the cases that Portland cement type 1 is applied I mean this type of cement can be used where a special cautious action is not considered.
Row | Type of Cement | Type of Test | Forced limits matching Iran Standard under No. ISIRI389 | Delijan Cement Specs |
4 | Portland Cement Type 2 | 3 day Compressive Strength | Min 100 kg/cm2 | 260+_ 10 kg/cm2 |
7 day Compressive Strength | Min 175 kg/cm2 | 400+_ 10 kg/cm2 | ||
28 day Compressive Strength | Min 270 kg/cm2 | 520+_ 15 kg/cm2 |